Water Cooled VRV (RWEYQ) - For Geothermal or Boiler/Tower Applications
The VRV IV-W Series offers an energy saving alternative to traditional centralized equipment. Its remarkable compact and light weight structure makes installation of VRV technology in large buildings possible. At only 330 lbs. and less than 40” high, the VRV IV-W Series can take a ride up the elevator to be installed in a machine room. Offering state of the art comfort for hotels, offices and large commercial applications, the engineer solution tool box just got bigger. The VRV system keeps running costs at an absolute minimum by controlling each zone individually and being able to shut down completely in unoccupied areas.
VRV IV-W Series Systems are equivalent to 4-Pipe chilled water systems, but also offer a viable alternative to WSHP Solutions. Each connected Indoor Unit can provide heating and cooling independently to suit zone requirements making these systems suitable for both open plan, or cellular applications with different operation requirements.
Two Stage Heat (Energy) Recovery is available between indoor units on the same VRV system and then across all the systems connected to a common water loop. This has a dramatic impact on Power Consumption and helps improves energy efficiency.
The VRV IV-W Series allows for extensive refrigerant piping, enabling several spaces to be cooled by a single refrigerant circuit. The VRV IV-W Series uses the same Daikin inverter technology that is used with air-cooled systems, but extends the application of VRV products by utilizing the same quality family of VRV indoor units and controls options.
Water-Side Infrastructure & Components
- A water loop system is routed around the building, either vertically or horizontally. This can be either plastic or steel pipe work.
- Heat Injection (Boilers) and Rejection (Cooling Tower or Dry Coolers) are required to ensure that the water loop stays between the required design conditions of 67 and 95 ° F.
- VRV IV-W Series condensers are connected to the water loop and the connecting refrigerant circuit serves indoor units the same as any Air cooled VRV system.
- The following Water Side components are required:
- Strainer (Mandatory – Field Supplied)
- Flow Switch or Differential Pressure Switch (Essential)
- Thermostat (For Water Temperature)
- Circulation Pumps
- Adjustable Flange
- Operation Range of Water Volume is 13.2 ~ 39.5 gpm. The optimum water volume is 16 gpm or more.
- The Operation range for Inlet Water Temp is 50 ~ 113 F. The Optimum Water Temp Range is 67 ~ 95 F.
- The Geothermal Operation range for Inlet Water Temp is 14 ~ 95 F during heating operation, and 27 ~ 113 F during cooling operation.
Standard VRV IV-W
Standard VRV IV-W Specifications
Specification | Application Rules |
---|---|
Water Flow Rate (minimum) | 16.4 - 38.5 (13.2) gpm [62-150 (50) l/m] |
Water Temp Range Cooling | 50 - 113 ° F (10 - 45 ° C) |
Water Temp Range Heating | 50 - 113 ° F (10 - 45 ° C) |
Water Temp Range Simultaneous Cooling & Heating | 50 - 113 ° F (10 - 45 ° C) |
Glycol Allowance | 0 - 50% |
Glycol Type | Propylene / Ethylene |
Connection Ratio | 50 - 130% |
Geothermal Enhanced VRV IV-W
Geothermal Enhanced VRV IV-W Specifications
Specification | Application Rules |
---|---|
Water Flow Rate | 21 - 40 gpm (80 - 150 l/m) |
Water Temp Range Cooling | 48 (27)* - 113 ° F (9 (-3) - 45 ° C) |
Water Temp Range Heating | 14 - 113 ° F (-10 - 45 ° C) |
Water Temp Range Simultaneous Cooling & Heating | 48 - 113 ° F (9 - 45 ° C)** |
Glycol Allowance | 0 - 50%*** |
Glycol Type | Propylene / Ethylene |
Connection Ratio | 50 - 130% |
*Application rules apply below 48 ° F. Please contact your local Daikin office for design assistance and approval.
** EWT in simultaneous heating and cooling operation can be lower than 48°F if the condenser is in heating dominant heat recovery operation. (contact your local Daikin office for further details)
*** EWT operation range is limited to 23°F (-5°C) with 30% glycol, 40-50% glycol must be used with water temperatures below 23°F down to a limit of 14°F.
- The Condensing Unit Heat Rejection Rate is:
- RWEYQ72 - 0.64kW / Hour
- RWEYQ84 - 0.71kW / Hour
The Water Flow Head Loss is:
Water Volume gpm 13.2 15.9 25.4 31.7 39.6 Head Loss ftH20 3.78 6.36 8.87 13.25 17.56
Condensing Units - Water Cooled
Tonnage | 6 | 7 | 12 | 14 | 18 | 21 | |
---|---|---|---|---|---|---|---|
Unified Heat Pump/Heat Recovery 208- 230V & 460V |
No. of Condensing Unit Modules | 1 | 1 | 2 | 2 | 3 | 3 |
Max No. of Indoor Units | 12 | 14 | 24 | 29 | 36 | 36 | |
No. of Inverter Compressors | 1 | 1 | 2 | 2 | 3 | 3 | |
Appearance |
Indoor Units
Indoor Type | Capacity (kbtu/h) | 5.8 | 7.5 | 9.5 | 12 | 15 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 72 | 96 | Application Considerations | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ducted | High airflow/Low sound Up to 0.8" ESP Less than 12" height MERV filtration |
||||||||||||||||
High airflow/Low sound Up to 0.8" ESP Less than 10" height MERV filtration |
|||||||||||||||||
Low sound level auto fan speed control Up to 0.6" ESP Less than 10" height |
|||||||||||||||||
Low sound level auto fan speed control Up to 0.6" ESP Less than 10" height |
|||||||||||||||||
Low sound level auto fan speed control Up to 0.6" ESP Less than 10" height |
|||||||||||||||||
Hotels/Dorms Rear or bottom suction return Less than 8" height |
|||||||||||||||||
FXTQ_TAVJU |
Replacement/Retrofit Residential/Multi-family Auto fan logic |
||||||||||||||||
Large/Open plan areas Up to 0.95" ESP MERV filtration |
|||||||||||||||||
Concealed installtions Under window installations Less than 9" depth |
|||||||||||||||||
Non-Ducted | Open plan areas Classrooms/Retail Multiple airflow patterns |
||||||||||||||||
Office/Retail Energy efficient fan motor Stylish unit Air temperature sensor |
|||||||||||||||||
Office/Retail Low sound level Three auto swing positions Less than 12" height |
|||||||||||||||||
Office/Retail Low sound level Independently motorized louvers Less than 12" high |
|||||||||||||||||
Hotel Rooms / Offices / Residential (Apartments,Condominiums, etc.) | |||||||||||||||||
Narrow/Retrofit installations Less than 8" height Wide airflow |
|||||||||||||||||
Compact, flat panel design Auto swing for wide air discharge |
|||||||||||||||||
Replacement/Retrofit Under window installations less than 9" depth |
|||||||||||||||||
Zoning | Adds Multi-Zone capability for 2-6 zones |
Comfort Cooling/Heating
Outside air connection possible
Condensate pump standard
Water Cooled VRV
Water cooled VRV systems are equivalent to 4-pipe chilled water systems, but also offer a viable alternative to water-source heat pump solutions. Each connected indoor unit can provide heating or cooling independently to suit zone requirements, making these systems suitable for both open plan spaces and individual zones with varying temperature requirements.
|
1. Brazed plate heat exchanger
Refrigerant-to-water heat transfer is accomplished using a high efficiency, brazed plate heat exchanger. Water pressure drop through the heat exchanger is minimized, and an industry leading water temperature range allows for entering water temperatures as low as 27°F in cooling and 14°F in heating.
The brazed plate heat exchanger also enables a much more compact design over other types of heat exchangers, which contributes to such a low footprint.
2. High efficiency compressor
Daikin’s unique scroll compressor minimizes heat loss and is driven by a high efficiency motor to achieve significant Energy savings.
*High thrust mechanism:
By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.
3. Smooth sine wave DC inverter
By adoption of the Sine Wave, which smoothes the rotation of the motor, operation efficiency is greatly improved.
4. Integrated water loop control
An integrated operational output allows the water cooled VRV system to energize and de-energize pumps or open and close isolation valves when the system is not in operation. An integrated flow proving input provides an interface for a water loop flow meter to ensure the system’s compressors do not operate if there is a loss of flow in the water loop.
5. Compact design
The water-cooled VRV design is based on a modular concept; all water-cooled condensers are of the same dimensions, and are available in 6-Ton and 7-Ton modules. With a footprint of only 4.6 square feet, a height of only 39 inches, and the ability to stack modules, a 28-ton system requires only about 10 square feet of floor space.
- Unified heat pump or heat recovery (simultaneous operation) condensing unit.
- 6, 7, 12, 14, 18 and 21 ton, 208 - 230V and 460V / 3-phase power for commercial applications.
- 7 combinations of condensing unit, up to 21-ton serving up to 36 indoor units.
- Up to 1,024 indoor units can be operated on a single wiring system.
- Continuous operation allows for cold climate capability delivering comfortable heating performance with no defrost.
- Long refrigerant lines, up to 980 feet of pipe (390 feet max. linear liquid piping length), 164 feet height difference.
- The System (Braze Plate Heat Exchanger) can tolerate water pressure up to 285 psi (or 640 ft. of Head).
- Optimum water flow rates per module of 16 gpm or greater (operable range 13.2 ~ 39.5 gpm).
- Modular units can be interconnected to make combinations of up to 21 tons systems.
- Operates with closed loop cooling tower, dry cooler, boiler, and geothermal solutions.
- System diversity up to 130% connectivity of nominal capacity.
- Compact size, 39-3/8” in height, 30-3/4” wide and just 330lbs. Modular cabinet enables stacked multiple unit installations.
- The advanced, self-diagnostic, auto-check function will detect a malfunction and immediately display the type and location so it can be resolved quickly and effectively.
- RWEYQ condensing unit sound level as low as 50dB(A).
- Zone LCD Remote Controller for up to 16 zones and provides a host of operational functions, including 7-Day Programmability.
- Connects to the full suite of advanced Daikin Control Solutions including I-Touch Controller and I-Touch Manager.
- Can be integrated to Open Protocol Building Management Systems via the Daikin BACnet® and LonWorks® interfaces.